Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Arq. bras. oftalmol ; 86(5): e20230064, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513681

RESUMO

ABSTRACT Purpose: The study aimed to evaluate the clinical and tissue response to a hollow polymethylmethacrylate orbital implant with a multiperforated posterior surface in an animal model after evisceration. Methods: Sixteen New Zealand rabbits had their right eye eviscerated. All animals received a hollow polymethylmethacrylate implant 12 mm in diameter that is multiperforated in its posterior hemisphere. The animals were divided into four groups, and each one had the eye exenterated at 7, 30, 90, and 180 days post-evisceration. Clinical signs were assessed daily for 14 days post-evisceration and then every 7 days until 180 days. Inflammatory pattern, collagen structure, and degree of neovascularization generated with implant placement were analyzed with hematoxylin-eosin, picrosirius red, and immunohistochemistry staining. Results: There were no signs of infection, conjunctival or scleral thinning, or implant exposure or extrusion in any animal during the study. On day 7, the new tissue migrated into the implant and formed a fibrovascular network through the posterior channels. Inflammatory response reduced over time, and no multinuclea­ted giant cells were found at any time. Conclusion: Hollow polymethylmethacrylate orbital implants with a multiperforated posterior surface enable rapid integration with orbital tissues by fibrovascular ingrowth. We believe that this orbital implant model can be used in research on humans.


RESUMO Objetivo: Avaliar a resposta tecidual e clínica a um implante orbitário de polimetilmetacrilato, oco e multiperfu­rado em sua porção posterior em modelo animal após evisceração. Métodos: Dezesseis coelhos da raça Nova Zelândia foram submetidos à evisceração do globo ocular direito. Todos receberam implante oco de polimetilmetacrilato de 12 mm de diâmetro, multiperfurado em sua semiesfera posterior. O estudo foi dividido em avaliação clínica e histopatológica. A avaliação clínica foi diária até 14 dias pós-evisceração e, a cada sete dias, até completar 180 dias. Os animais foram divididos em grupos de quatro animais e cada um foi submetido à exenteração com 07, 30, 90 e 180 dias e depois à eutanásia. A análise histopatológica teve por fim caracterizar o padrão inflamatório, a estrutura do colágeno e o grau de neovascularização. Para isso, além da tradicional coloração pela hematoxilina-eosina, utilizou-se o corante Picrosirius Red (PSR) e imuno-histoquímica com o marcador CD 34. Resultados: Não houve sinais de infecção, afinamento conjuntival ou escleral, exposição ou extrusão do implante em nenhum animal durante o estudo. Já no sétimo dia, o tecido neoformado migrou para dentro do implante formando uma rede fibrovascular através dos canais posteriores. A resposta inflamatória diminuiu ao longo do tempo avaliado e não foram encontradas células gigantes multinucleadas. Conclusão: O implante analisado permite a sua integração aos tecidos orbitários pelo crescimento fibrovascular em seu interior. Os autores acreditam que este modelo de implante orbital pode fazer parte de testes com humanos.

2.
Arq. bras. oftalmol ; 83(1): 62-64, Jan.-Feb. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1088956

RESUMO

ABSTRACT We present a patient who underwent evisceration surgery after spontaneous rupture of the ocular globe due to long-data uncontrolled glaucoma, with posterior placement of an orbital implant made of a bone cement compound based on polymethylmethacrylate as alternative materials were not available. Such a compound is characterized by excellent biocompatibility and low cost, which makes it an interesting alternative for treatment. The anophthalmic socket was successfully filled, providing proper esthetic results and favorable conditions for the posterior scleral prosthesis implantation. No complications were observed during 10 months of follow-up. We believe that, in the absence of alternative materials, low-cost materials may be used in emergency settings to repair anophthalmic cavities and provide satisfactory functional and esthetic outcomes.


RESUMO Apresentamos um paciente que foi submetido à cirurgia de evisceração após ruptura espontânea do globo ocular devido a glaucoma não controlado de longa data, com posterior colocação de implante orbital feito de cimento ósseo, composto à base de polimetilmetacrilato, diante da indisponibilidade de materiais alternativos. Tal composto se caracteriza pela excelente biocompatibilidade e baixo custo, o que o torna uma alternativa interessante para o tratamento. A cavidade anoftálmica foi preenchida com sucesso, fornecendo resultados estéticos adequados e condições favoráveis para o implante posterior de prótese escleral. Nenhuma complicação foi observada durante os 10 meses de seguimento. Acredi­tamos que, na ausência de materiais alternativos, materiais de baixo custo podem ser usados em situações emergenciais para preencher cavidades anoftálmicas e prover resultados funcionais e estéticos satisfatórios.


Assuntos
Humanos , Masculino , Idoso , Órbita/cirurgia , Cimentos Ósseos , Implantes Orbitários , Ruptura Espontânea/cirurgia , Ruptura Espontânea/etiologia , Materiais Biocompatíveis , Glaucoma/complicações , Evisceração do Olho , Procedimentos de Cirurgia Plástica
3.
Arq. bras. oftalmol ; 83(1): 33-38, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088945

RESUMO

ABSTRACT Purposes: To identify problems caused by prosthesis-socket volume imbalances in anophthalmic sockets; and to evaluate rehabilitation with dermofat graft as a solution. Methods: We retrospectively reviewed medical records of patients operated in our clinic (between May 2011 and June 2016) with dermofat grafts to treat anophthalmic socket-related problems. During the preoperative examinations, ophthalmologists recorded the presence of eyelid problems due to the socket volume deficit, upper and lower fornix deficiency, deepening in the upper eyelid sulcus, epiphora and secretion, lower eyelid laxity, ptosis, entropion, and ectropion. Following the surgical repair, new prosthesis suitable for the resulting socket area were implemented for all the patients. The mean follow-up period was 27.42±16 months (ranging from 10-62 months). On the last control examinations, ophthalmologists recorded solved and unsolved socket problems that were present preoperatively. Results: We included 16 men and 5 women in this study. The mean age was 38.3 ± 18.4 years (range, 5-75 years). The mean duration of preoperative prosthesis use was 9.4 ± 6.8 years (range, 1-30 years). Preoperatively, 7 patients had only orbital volume deficits, and 14 had socket volume displacements in addition to the volume deficits. After the dermofat graft implantations, the remaining deficits were corrected during another surgical session: 6 patients underwent ptosis corrections, 5 lateral canthal suspensions, 5 lower fornix with mucosal graft formations, and 2 upper fornix formations with mucosal grafts. All patients were able to use prosthesis postoperatively. Conclusion: The use of dermofat grafts to correct anophthalmic socket problems caused by orbital volume deficits or volume displacements is an effective, reliable, and reproducible surgical method.


RESUMO Objetivos: Identificar os problemas causados pelo desequilíbrio do volume da cavidade da prótese em cavidades anoftálmicas, e avaliar a reabilitação com enxerto de dermofato como solução. Métodos: Revisamos retrospectivamente os prontuários de pacientes operados em nossa clínica (entre maio de 2011 e junho de 2016) com enxertos de dermofato para tratar problemas relacionados a cavidades anoftálmicas. Durante os exames pré-operatórios, os oftalmologistas registraram a presença de problemas palpebrais devido ao déficit de volume, deficiência de fórnice superior e inferior, aprofundamento no sulco palpebral superior, a epífora e secreção, flacidez palpebral inferior, ptose, entrópio e ectrópio. Após a cirurgia, novas próteses adequadas para a área de encaixe foram implementadas em todos os pacientes. O tempo médio de acompanhamento foi de 27,42 ± 16 meses (variando de 10 a 62 meses). Nos últimos exames de controle, os oftalmologistas registraram problemas corrigidos e não corrigidos da cavidade que estavam presentes no pré-operatório. Resultados: Foram incluídos 16 homens e 5 mulheres neste estudo. A média de idade foi de 38,3 ± 18,4 anos (variação de 5-75 anos). A duração média do uso de prótese pré-operatória foi de 9,4 ± 6,8 anos (variação de 1 a 30 anos). No pré-operatório, 7 pacientes apresentavam apenas déficit orbitais e 14 tinham desvios de volume, além dos déficits de volume. Após os implantes de enxerto de dermoadipação, os déficits remanescentes foram corrigidos durante outra sessão cirúrgica: 6 pacientes foram submetidos a correção de ptose, 5 suspensões de cantal lateral, 5 fórnix inferior com enxerto de mucosa e 2 formações de fórnice superior com enxerto de mucosa. Todos os pacientes foram capazes de usar prótese no pós-operatório. Conclusão: A utilização de enxertos de dermofato para corrigir problemas de anoftalmia causados por déficits de volume orbital ou deslocamento de volume é um método cirúrgico eficaz, confiável e reprodutível.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Órbita/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Anoftalmia/cirurgia , Procedimentos de Cirurgia Plástica/efeitos adversos , Implantes Orbitários/efeitos adversos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Estudos Retrospectivos , Procedimentos de Cirurgia Plástica/métodos , Pálpebras/cirurgia
4.
Arq. bras. oftalmol ; 82(6): 471-475, Nov.-Dec. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1038699

RESUMO

ABSTRACT Purpose: To evaluate the biocompatibility of three-dimensional (3D) printed orbital spheres for evisceration. Materials: A total of 10 consecutive patients (eight females and two males; mean age, 46.8 ± 14.2 years) underwent evisceration of blind painful eyes. 3D spherical implants produced by a rapid prototype machine were used to restore orbital volume. The implants were produced from a commercially available photocurable resin (Fullcure®). Systemic toxicity was evaluated by comparing serum biochemical measurements (creatine phosphokinase, aspartate aminotransferase, alanine aminotransferase, albumin, creatinine, urea, alkaline phosphatase, and C-reactive protein) before and at 12 months after surgery. Local toxicity was assessed by the evaluation of signs of socket inflammation at the first postoperative month. Changes in implant size were determined by computed tomography scans at 2 and 12 months after surgery. Results: The postoperative evaluations were uneventful. The biochemical evaluation showed no significant changes after surgery. None of the patients presented signs of orbital implant inflammation, infection, exposure, or extrusion. Computed tomography scan evaluations revealed no changes in implant size. Conclusion: To the best of our knowledge, this is the first phase-1 clinical study to certify the biocompatibility of the Fullcure resin for orbital implants in humans. The 3D printing technology permits fast and accurate production of implants for this purpose.


RESUMO Objetivos: Avaliar a biocompatibilidade das esferas produzidas por impressora tridimensional em evisceração. Pacientes e métodos: Evisceração por olho cego doloroso foi realizada em 10 pacientes consecutivos (8 mulheres, idade média: 46.8 ± 14.2 anos). Os implantes esféricos foram produzidos pelo sistema de prototipagem rápida utilizando dados tridimensionais computadorizados. O material utilizado para produção dos implantes foi a resina fotocurável Fullcure®. A avaliação da toxicidade sistêmica do material foi realizada por meio da dosagem de marcadores bioquímicos (creatina fosfoquinase, aspartato aminotransferase, alanina aminotransferase, albumina, creatinina, ureia, fosfatase alcalina, e proteína C-reactiva) antes da cirurgia e aos 12 meses de pós-operatorio. A avaliação da toxicidade local foi realizada por meio do registro qualitativo dos sinais inflamatórios no lado operado durante o primeiro mês de pós-operatório. O tamanho dos implantes foi medido em tomografias computadorizadas (CT) aos 2 e 12 meses de pós-operatório. Resultados: A avaliação bioquímica mostrou que os marcadores estudados não sofreram alterações significativas após a cirurgia. Nenhum paciente apresentou sinais de inflamação atípica, infecção, exposição ou extrusão. A avaliação tomográfica não demonstrou mudanças nos tamanhos dos implantes. Conclusão: O presente trabalho é o primeiro estudo clínico realizado para atestar a biocompatibilidade dos implantes orbitais de resina fotocurável Fullcure. A produção dos implantes pela técnica de impressão tridimensional, utilizando essa resina, permite a disponibilização rápida e acurada do produto final


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Polímeros/normas , Evisceração do Olho/métodos , Implantes Orbitários/normas , Impressão Tridimensional/normas , Período Pós-Operatório , Desenho de Prótese , Valores de Referência , Fatores de Tempo , Materiais Biocompatíveis/normas , Teste de Materiais , Reprodutibilidade dos Testes , Resultado do Tratamento
5.
Rev. bras. cir. plást ; 32(2): 181-189, 2017. ilus, tab
Artigo em Inglês, Português | LILACS | ID: biblio-847355

RESUMO

Introdução: A reconstrução dos defeitos no assoalho orbital após fraturas constitui um desafio ao cirurgião plástico, pois além da expectativa estética e reconstrutora do paciente, cabe o tratamento de possíveis complicações funcionais, como diplopia e parestesias faciais. O objetivo é demonstrar uma série de casos utilizando cartilagem auricular conchal para reposição volumétrica orbital e estrutural do assoalho. Métodos: Foram avaliados 24 pacientes, operados pelo autor deste trabalho no período de 2013 a 2016, por motivo de fraturas de assoalho orbital pura (blow-out) ou impura (conjugadas a lesões de margem orbital, como zigoma e maxila). A técnica de estruturação do assoalho utilizou enxerto cartilaginoso autólogo conchal em todos os casos. Os pacientes foram catalogados quanto à presença de queixas pré-operatórias, como parestesia e diplopia, e sintomas, como enoftalmia, assim como resultados pós-operatórios. Resultados: A presença de lesões concomitantes como fratura de complexo zigomático e fratura maxilar pode influenciar no sucesso da reconstrução, assim como as fraturas com maior área de descontinuidade no assoalho orbital. Poucos pacientes apresentaram queixas pós-operatórias e somente dois casos (9,2%) necessitaram de nova abordagem cirúrgica. Conclusão: A cartilagem conchal auricular autóloga é um material adequado à reconstrução de defeitos no assoalho orbital pós-fratura, apresentando como vantagens a fácil obtenção, baixa morbidade, cicatriz inconspícua, excelente adaptação ao formato do assoalho da órbita e consequente reposição volumétrica.


Introduction: The reconstruction of defects in the orbital floor after fractures poses a challenge to the plastic surgeon because besides the patient's aesthetic and reconstructive expectations, possible functional complications such as diplopia and facial paresthesia must be treated. This study aimed at reporting a series of cases in which conchal auricular cartilage was used for volumetric orbital and structural replacement of the floor. Methods: Twenty-four patients, with surgery performed by the author, between 2013 and 2016, for pure (blow-out) or impure (conjugated to orbital margin injuries, such as zygoma and maxilla) orbital floor fractures, were evaluated. The repair technique involved autologous conchal cartilage graft in all cases. Patients were classified for the presence of preoperative complaints, including paresthesia and diplopia, and symptoms such as enophthalmia, as well as postoperative outcomes. Results: The existence of concomitant lesions, such as zygomatic complex and maxillary fracture, as well as fractures with greater discontinuity in the orbital floor, may influence the success of reconstruction. Few patients exhibited postoperative complaints and only two (9.2%) required a new surgical approach. Conclusion: Autologous conchal auricular cartilage is a suitable material for reconstruction of defects in the post-fracture orbital floor, possessing various advantages, including ease of attainment, low morbidity, inconspicuous scar, and excellent adaptation to the shape of the orbital floor and consequent volumetric replacement.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , História do Século XXI , Órbita , Fraturas Orbitárias , Parestesia , Procedimentos de Cirurgia Plástica , Implantes Orbitários , Cartilagem da Orelha , Órbita/cirurgia , Órbita/lesões , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/terapia , Parestesia/cirurgia , Parestesia/complicações , Parestesia/reabilitação , Prontuários Médicos , Prontuários Médicos/normas , Procedimentos de Cirurgia Plástica/métodos , Cartilagem da Orelha/cirurgia , Cartilagem da Orelha/transplante
6.
Arq. bras. oftalmol ; 76(3): 141-146, maio-jun. 2013. ilus, graf
Artigo em Português | LILACS | ID: lil-681844

RESUMO

OBJETIVO:Avaliar a biocompatibilidade de material FullCure 720®, que é uma resina, na confecção de implante orbitário. Avaliou-se a resposta clínica dos animais, toxicidade sistêmica e a resposta inflamatória crônica. Os animais foram pesados, exames bioquímicos e resposta inflamatória foram avaliados. Foi efetuada evisceração e colocado implante esférico orbitário. Os animais foram acompanhados durante o período de 60 dias, onde se avaliou o comportamento clínico e sinais locais. Após este período, procedeu-se a eutanásia seguida da enucleação. Foi realizada análise macroscópica e histomorfométrica. Os resultados revelaram comportamento normal dos animais, com ausência de exposição ou extrusão dos implantes, morte de algum animal e ausência de toxicidade sistêmica. Houve formação de uma cápsula fibrosa entre a capa escleral e o implante orbitário, resposta inflamatória considerada normal quando em contato com o tecido do coelho. A resina FullCure 720® utilizada como implante orbitário, mostrou-se biocompatível neste estudo.


PURPOSE: To evaluate the resin FullCure 720® biocompatibility as orbital implant. Clinical response and signs of systemic toxicity to the resin were evaluated, local biocompatibility and microscopic analysis regarding chronic local inflammatory response to the implant. The animals were weighted, biochemical exams and inflammatory response were evaluated. All animals were eviscerated and implantation of the spheres was carried out. Animals were followed for 60 days. Clinical behavior of animals and local signals of inflammation had been observed. After this period animals underwent euthanasia followed by enucleation. Macroscopic and histomorphometric analysis were performed. The results showed normal behavior of the animals, without implant exposure, extrusion, death or systemic toxicity. Capsule tissue formation was observed between the sclera and the implant. Normal inflammatory response to the foreign material in contact with the rabbit soft tissue was observed. The resin FullCure 720®, demonstrated to be biocompatible as an orbital implant in this study.


Assuntos
Animais , Masculino , Coelhos , Resinas Acrílicas/toxicidade , Materiais Biocompatíveis/toxicidade , Teste de Materiais , Implantes Orbitários , Resinas Acrílicas/uso terapêutico , Modelos Animais , Implantação de Prótese/métodos , Reprodutibilidade dos Testes , Propriedades de Superfície , Esclera/efeitos dos fármacos , Fatores de Tempo
7.
Arq. bras. oftalmol ; 75(4): 267-272, jul.-ago. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-659622

RESUMO

PURPOSE: To evaluate histologically the integration process of cellulose gel produced by Zoogloea sp when implanted into rabbits' eviscerated eyes. METHODS: This experimental study employed 36 eyes of 18 rabbits subjected to evisceration of their right eyes. The sclerocorneal bag was sutured and filled with biopolymer from sugar cane in the gel state. All animals were clinically examined by biomicroscopy until the day of their sacrifice which occurred on the 7th, 30th, 60th, 90th, 120th, or 240th day. The eyeballs obtained, including the left eyes considered controls were sent for histopathological study by optical macroscopy and microscopy. Tissue staining techniques used included hematoxylin-eosin, Masson trichrome (with aniline), Gomori trichrome, Van Gienson, Picrosirius red, and periodic acid-Schiff (PAS). RESULTS: No clinical signs of infection, allergy, toxicity, or extrusion were observed throughout the experiment. The corneas were relatively preserved. Macroscopic examination revealed a decrease of ~ 8% in the volume of the bulbs implanted with the biopolymer. After cutting, the sclerocorneal bag was solid, compact, elastic, and resistant to traction, with a smooth and whitish surface, and showed no signs of necrosis or liquefaction. The episcleral tissues were somewhat hypertrophied. The histological preparations studied in different colors revealed an initial lymphoplasmacytic infiltration, replaced by a fibroblastic response and proliferation of histiocytes, along with formation of giant cells. Few polymorphonuclearneutrophils and eosinophils were also found. Neovascularization and collagen deposition were present in all animals starting from day 30; although on the 240th day of the experiment the chronic inflammatory response, neovascularization and collagen deposition had not yet reached the center of the implant. CONCLUSION: In this model, the cellulose gel produced by Zoogloea sp proved to be biocompatible and integrated into the orbits. Morphometric, immunohistochemical and biodegradability studies should be performed in the future.


OBJETIVOS: Avaliar histologicamente o processo de integração do gel da celulose produzida pela Zoogloe asp implantado em olhos eviscerados de coelhos. MÉTODOS: Estudo experimental utilizando 36 olhos de 18 coelhos. Todos eles tiveram seus olhos direitos eviscerados. A bolsa escleral foi suturada e preenchida com biopolimero da cana de açúcar, no estado gel. Todos os animais foram examinados clinicamente, sob biomicroscopia, até o dia de seus sacrifícios e enucleações que aconteceram no 7º, 30º, 60º,90º,120º e 240º dia. Os bulbos obtidos, inclusive os esquerdos, considerados controles, foram encaminhados para estudo histopatológicos de macroscopia e microscopia óptica. As colorações pela hematoxilina-eosina, tricômio de Masson (com anilina), tricômio de Gomori, Van Gienson e Picrosirius red e ácido periódico de Schiff (PAS) foram usadas. RESULTADOS: Durante o experimento não foram observados sinais clínicos de infecção, alergias, intoxicação ou extrusão. As córneas apresentavam-se relativamente preservadas. Exame macroscópico revelou uma diminuição de aproximadamente 8% no volume dos bulbos nos quais o biopolímero foi implantado. O corte do saco escleral mostrou um conteúdo sólido, compacto, elástico, resistente à tração, com superfície lisa e brancacenta. Não foram observados sinais de necrose, ou liquefação. O tecido epiescleral estava algo hipertrofiado. As preparações histológicas estudadas, nas diversas colorações, revelaram uma infiltração linfomonomorfonuclear inicial, substituída posteriormente por uma resposta fibroblástica e proliferação de histiócitos com formação de células multinucleadas gigantes. Foram também encontrados poucos polimorfonucleares neutrófilos e eosinófilos. A partir do 30º dia houve proliferação vascular e deposição de calágeno em todos os espécimes estudados, embora, no 240º dia do experimento, a resposta inflamatória crônica, a neovascularização e a deposição do colágeno não tinham ainda atingido o centro do implante. CONCLUSÃO: Neste modelo, o gel da celulose produzido pela Zoogloea sp, mostrou-se biocompatível e integrado às órbitas. Estudos morfométrico, imuno-histoquímico e de biodegradabilidade devem ser realizados futuramente.


Assuntos
Animais , Coelhos , Materiais Biocompatíveis/uso terapêutico , Biopolímeros/uso terapêutico , Evisceração do Olho , Implantes Orbitários , Modelos Animais de Doenças , Microscopia Acústica , Fatores de Tempo
8.
Rev. bras. oftalmol ; 71(4): 221-225, jul.-ago. 2012. tab
Artigo em Português | LILACS | ID: lil-650653

RESUMO

OBJETIVO: Determinar o perfil clínico dos pacientes submetidos à reconstrução da cavidade orbitária com implante de Mules. MÉTODOS: Foi realizado um estudo epidemiológico com delineamento transversal, baseado na análise dos prontuários de pacientes submetidos à cirurgia de enucleação ou evisceração do globo ocular assistidos no Departamento de Plástica Ocular e Órbita do Hospital Regional de São José (HRSJ) entre dezembro de 1999 a dezembro de 2009. As variáveis utilizadas foram: idade, sexo, cirurgia realizada, indicação, tamanho do implante e complicações pós-operatórias associadas. RESULTADOS: A análise incidiu sob registros de 68 pacientes, com predomínio do gênero masculino (60,3%) cuja média de idade foi de 38,4 anos. Adultos jovens destacaram-se com a maior frequência de perda do globo ocular. As principais etiologias que cursaram com a enucleação ou evisceração do globo ocular foram trauma ocular, glaucoma, melanoma de coróide e phthisis bulbi. O trauma ocular apresentou maior prevalência no sexo masculino (p<0,01). As complicações pós-cirúrgicas com maior frequência foram expulsão ou extrusão do implante (20,6%) e retração de cavidade ocular (5,9%). CONCLUSÃO: As principais causas de perda do globo ocular foram trauma ocular, glaucoma, melanoma de coroide e phthisis bulbi. As complicações pós-cirúrgicas após implante de Mules foram expulsão ou extrusão do implante e retração de cavidade ocular. Os implantes de 15 e 16 mm apresentaram maior assiduidade e o tamanho da esfera não interferiu no risco de extrusão.


OBJECTIVE: To access the patient's profile after enucleation or evisceration of ocular globe using mules implant. METHODS: An epidemiological study with a cross-sectional design was conducted, based on analysis of medical records of patients who underwent enucleation or evisceration of the eyeball assisted in the Department of Ocular Plastic and Orbit of the HRSJ from December 1999 to December 2009. The variables used were age, sex, surgery, indication, size of implant and postoperative complications associated. RESULTS: A total of 68 patients were analyzed. The mean age was 38,4 years and the most prevalent genre was male (60.3%). Young adults stood out with greater frequency of loss of the eyeball. The main etiologies presenting with enucleation or evisceration of the eyeball were ocular trauma, glaucoma, choroidal melanoma and phthisis bulbi. The ocular trauma was more prevalent in males (p<0.01). The postoperative complications more frequently were expulsion or extrusion of the implant (20.6%) and retraction of the orbital cavity (5.9%). CONCLUSION: The main causes of loss of the eyeball were ocular trauma, glaucoma, choroidal melanoma and phthisis bulbi. The postoperative complications after Mules´ implant were expulsion or extrusion of the implant and retraction of the orbital cavity. The implants 15 and 16 mm showed greater frequency and the size of the ball did not affect the risk of extrusion.


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Enucleação Ocular , Olho Artificial , Perfil de Saúde , Implantes Orbitários/efeitos adversos , Exenteração Orbitária , Estudos Transversais , Estudos Epidemiológicos , Prontuários Médicos
9.
Rev. bras. oftalmol ; 71(4): 227-232, jul.-ago. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-650654

RESUMO

OBJETIVO: Alterações oculares, em especial a perda de volume nas cavidades evisceradas, promovem uma série de modificações ao paciente tanto funcional do órgão quanto psicológica e estética. Para tanto a procura de um material de baixo custo e com biocompatibilidade tem sido uma constante na literatura. Portanto, esse trabalho teve como objetivo testar experimentalmente implante de polietileno granulado de ultra-alto peso molecular, material de baixo custo, em órbitas de coelhos submetidos à evisceração cirúrgica em vários tempos experimentais, onde foram avaliados aspectos macroscópicos e microscópicose de toxicidade sistêmica do material. MÉTODOS: Para esse estudo foram utilizados coelhos Oryctolaguscuniculus submetidos à evisceração do globo ocular direito e posteriormente implantados com esfera de polietileno granulado de ultra-alto peso molecular e analisados por 15, 30, 90 e 180 dias pós-implante, com parâmetros macro, microscópios e bioquímicos. Os animais controles foram submetidos ao mesmo procedimento sem, entretanto a colocação do implante. RESULTADOS: Os resultados desse trabalho mostram que o material utilizado no implante de cavidade não apresenta alteração significativa nos parâmetros de peso e bioquímicos quando comparados ao grupo controle. O material implantado apresentou uma grande interação com o tecido do hospedeiro. CONCLUSÃO: Os resultados indicam que implante de polietileno granulado de alto peso molecular desenvolvido por uma indústria nacional tem alto potencial para se realizar testes em humanos.


OBJECTIVE: Ocular changes in special due to volume loss in eviscerated cavities promote several psychological aesthetic and functional alterations to patients. For this reason, searches aiming at finding a material of low cost and biocompatibility have been constantly carried out. Test experimentally the implants constituted of ultra-high molecular weight granular polyethylene oflow cost, in orbits of rabbits subjected to surgical evisceration in several experimental times, evaluating the macro and microscope aspects besides the systemic toxicity of the material. METHODS: In this study we eviscerated the right ocular globe of rabbits of the species Oryctolaguscuniculus, implanted posteriorly a sphere of granular polyethylene of ultrahigh molecular weight and analysed the effects through macro, micro and biochemical parameters during 15, 30, 90 and 180 days after implantation.The control group were submitted the same procedure without the implants. RESULTS: This paper shows that the material used in the cavity does not present significant alteration in the weight and in the biochemistry of the animal; a good assimilation (integration) of the material implanted by the tissue formed was observed inside the implant. CONCLUSION: The results indicate that ultra-high molecular weight granular polyethylene implant developed by a national industry presents excellent integration in the model used supporting further use in tests with humans.


Assuntos
Animais , Coelhos , Anoftalmia/cirurgia , Olho Artificial , Implantes Orbitários , Exenteração Orbitária , Polietilenos/uso terapêutico , Ensaio Clínico , Estudos Prospectivos
10.
Rev. bras. oftalmol ; 70(6): 411-415, nov.-dez. 2011. graf
Artigo em Português | LILACS | ID: lil-612917

RESUMO

OBJETIVO: Avaliar o uso do enxerto dermoadiposo no tratamento da cavidade anoftálmica. MÉTODOS: Estudo retrospectivo, do qual participaram 28 portadores de cavidade anoftálmica secundária, tratados com enxerto dermoadiposo. Os dados avaliados foram: idade, sexo, motivo da primeira cirurgia, tipo de cavidade, razão da opção pelo enxerto dermoadiposo, resultados e complicações. Os dados foram analisados segundo a frequência de ocorrência. RESULTADOS: dos 28 pacientes analisados, 19 (67,8 por cento) eram do sexo masculino, 46,4 por cento deles apresentando de 40 a 60 anos de idade. A principal causa da perda do olho foi o trauma (7 casos - 25,0 por cento). A cavidade onde mais se empregou o enxerto dermoadiposo foi a do tipo III (32,1 por cento). Como primeira cirurgia, a evisceração havia sido realizada em 13 casos, a enucleação em 11 e o enxerto de pele em dois pacientes e em outros dois, não havia informação sobre a primeira cirurgia a que haviam sido submetidos. A opção pelo enxerto dermoadiposo foi feita com a finalidade de repor volume na cavidade e, ao mesmo tempo, conseguir maior superfície anterior da cavidade, já que a maioria possuía cavidades contraídas. A maioria dos pacientes (53,6 por cento) não apresentou complicações, tendo sido a necrose do enxerto a complicação mais observada (32,1 por cento). O resultado final da cirurgia foi considerado bom em 71,4 por cento dos pacientes e ruim em 7,1 por cento. CONCLUSÃO: O enxerto dermoadiposo é uma técnica cirúrgica simples e de bons resultados para reposição de volume em cavidades anoftálmicas. Os autores estimulam o ensino da mesma nos serviços de treinamento de jovens cirurgiões.


PURPOSE: To evaluate the dermofat graft in the anophthalmic socket treatment. METHODS: A retrospective study including 28 anophthalmic cavity carriers treated with dermofat graft was carried out. The patients were analyzed according to age, sex, socket contraction degree, first surgery performed, reason for graft choice, procedure´s results and complications. The data were analyzed according to the frequency of occurrence. RESULTS: Nineteen (67.8 percent) of the 28 analyzed patients were male. According to age the majority of patients were between 40 to 60 years old (13 patients - 46.4 percent) and the most common cause of eyeball loss was trauma (seven cases - 25 percent). Anophthalmic socket type III was the most frequently observed (32.1 percent). The evisceration was the first procedure in 13 cases, enucleation in 11 and skin graft was done in two patients. Two patients came to the service after evisceration and did not provide any information about the first surgery. The choice to use the dermofat graft was to replace volume at the socket of 12 patients (42.8 percent). Most of the patients (53.6 percent) had no complications and graft necrosis was the problem most frequently observed (32.1 percent). The surgery was considered good in 71.4 percent and not good in only 7.1 percent. CONCLUSION: the dermofat graft is an efficient and easy technique to reconstruct the anophthalmic cavity. The authors suggest this procedure must be introduced in the medical training services since it provide good results.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Enucleação Ocular/reabilitação , Tecido Adiposo/transplante , Transplante de Pele/métodos , Exenteração Orbitária/reabilitação , Órbita/cirurgia , Retalhos Cirúrgicos , Transplante Autólogo , Bioprótese , Nádegas , Estudos Retrospectivos , Túnica Conjuntiva/cirurgia , Implantes Orbitários , Olho Artificial , Cápsula de Tenon/cirurgia , Músculos Oculomotores/cirurgia
11.
Arq. bras. oftalmol ; 74(6): 425-429, nov.-dez. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-613443

RESUMO

OBJETIVOS: Estudar os efeitos clínicos da secreção das glândulas salivares labiais na lubrificação das cavidades anoftálmicas secas, avaliar a durabilidade dos resultados e apresentar a técnica do transplante. A aplicação desse procedimento em cavidades anoftálmicas secas é inédita na literatura. MÉTODOS: Estudo prospectivo das cirurgias de enxertos glândulo-mucosos, compostos pela mucosa labial e glândulas salivares subjacentes, colocados no fórnice conjuntival de 5 pacientes com cavidades anoftálmicas que apresentavam grave xeroftalmia e retração dos fórnices conjuntivais. As cirurgias foram realizadas durante o período de julho/00 a janeiro/09. Dois pacientes já haviam sido tratados previamente com enxertos de mucosa ou de pele. A técnica do procedimento é descrita em detalhes. Os parâmetros que serviram para a análise comparativa dos resultados foram o quadro clínico, o aspecto do revestimento da cavidade, o ressecamento da superfície da prótese e a frequência do uso de colírios lubrificantes. RESULTADOS: Em todos os casos foi constatada a integração do enxerto e a melhora dos parâmetros avaliados. A evolução mostrou persistência e estabilidade dos resultados. CONCLUSÕES: A lubrificação da superfície da cavidade produzida pela secreção salivar mostrou ser eficiente, bem tolerada e constante, resultando maior conforto do uso da prótese. Infere-se que essa melhor lubrificação obtida ajuda a prevenir a evolução do processo de retração da cavidade. O transplante das glândulas salivares labiais para o fórnice conjuntival demonstrou ser um procedimento de fácil execução, acessível a qualquer cirurgião oftalmologista.


PURPOSE: To study the clinical effects of labial salivary glands' secretion used as ocular lubricant in anophthalmic cavities with severe xerophthalmia; to evaluate the evolution of the results; and to present the surgical technique. This procedure application in dry anophthalmic cavities is new in the literature. METHODS: Prospective study of patients presenting anophthalmic cavities with severe xerophthalmia and conjunctival fornix retraction treated with labial salivary glands transplantation to the conjunctival fornices. The surgeries were performed in five patients during the period of July 2000 to January 2009. In two cases the fornix retraction was previously treated with mucosa or skin graft. The surgical procedure technique is described in details. The postoperative comparative analysis was based on the clinical picture, the cavity surface aspect, the dryness of the cavity and prosthesis and the frequency of lubricant eye drops use. RESULTS: In all cases both graft integration and improvement of the evaluated parameters were observed. The evolution proved the persistence and stability of the results. CONCLUSION: The salivary secretion produced by the transplanted labial glands proved to be efficient as conjunctival lubricant, well tolerated and permanent, making the use of the prosthesis more comfortable. This improvement helps to prevent the progression of the cavity retraction process. Labial salivary glands graft into the anophtalmic cavity is a simple procedure and accessible to any ophthalmic surgeon.


Assuntos
Humanos , Anoftalmia/complicações , Doenças Palpebrais/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/métodos , Glândulas Salivares Menores/transplante , Xeroftalmia/cirurgia , Ilustração Médica , Cuidados Pós-Operatórios , Estudos Prospectivos , Glândulas Salivares Menores/cirurgia , Resultado do Tratamento
12.
Arq. bras. oftalmol ; 74(5): 330-334, set.-out. 2011. tab
Artigo em Português | LILACS | ID: lil-608403

RESUMO

A integridade da face é condição que interfere no cotidiano do indivíduo sendo que a perda do globo ocular tem um impacto psicológico, demandando uma condição de adaptação. Intervenções como a reparação protética parecem produzir mudanças nos âmbitos emocional e comportamental. Objetivo: Identificar os aspectos psicossociais relacionados à ausência unilateral do globo ocular e avaliar a adaptação dos pacientes usuários de prótese ocular. Métodos: Para realização da pesquisa foi utilizado como instrumento de coleta de dados um roteiro de entrevista adaptado aos objetivos desse trabalho. Este foi composto por duas partes, a primeira referente a dados gerais de identificação do paciente e aspectos socioeconômicos. A segunda parte incluiu dados específicos sobre a perda e reabilitação ocular com 31 questões. Vinte e oito pacientes voluntários foram entrevistados. Resultados: A maioria era do gênero masculino (53,57 por cento). A idade variou entre 11 e 67 anos. O trauma foi o fator etiológico prevalente (60,71 por cento). Foi encontrada diferença estaticamente significativa (p<0,05) entre os escores dos sentimentos da época da perda e atualmente (z Wilcoxon=-4,41; p<0,001). Conclusão: Os dados evidenciaram dificuldades emocionais no processo inicial de contato com a condição de perda do olho e o papel da prótese como elemento de inclusão social, ressaltando a relevância do trabalho em equipe e do acesso a serviços de protetização para a adaptação desses pacientes.


Facial integrity is a condition which interferes in the daily life of the individual. The loss of an eyeball has psychological impact, requiring adaptation. Interventions such as prosthetic repair seem to lead to emotional and behavioral change. Purpose: The objective of this study was to identify the psychosocial aspects related to unilateral anophthalmic socket and evaluate patient adaptation to prosthesis. Methods: All participants responded to a semi-structured interview. This was composed of two parts, the first regarding the general data of patient identification and socioeconomic aspects. The second part included information about eye loss and rehabilitation, with 31 questions. Twenty-eight volunteers were interviewed. Results: Most were male (53.57 percent). Ages ranged between 11 and 67. Trauma was the prevalent etiological factor (60.71 percent). A significant statistical difference (p<0.05) was found between the scores of the feelings of loss before and after prosthesis (z Wilcoxon=-4.41; p<0.001). Conclusions: The data showed emotional difficulties in the initial contact with the loss of an eye and the role of the prosthesis as an element of social inclusion, stressing the importance of teamwork and access to fitting services in adapting these patients.


Assuntos
Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Traumatismos Oculares/psicologia , Olho Artificial/psicologia , Adaptação Psicológica , Estudos Transversais , Traumatismos Oculares/reabilitação , Entrevista Psicológica , Fatores Socioeconômicos
13.
Arq. bras. oftalmol ; 73(1): 81-83, Jan.-Feb. 2010. ilus
Artigo em Português | LILACS | ID: lil-546054

RESUMO

Apresentamos um novo modelo de implante orbital unindo o baixo custo da esfera de luxite (PMMA) com as vantagens da utilização do polietileno poroso (Porex®). O novo modelo consiste de uma esfera de luxite na qual em sua face anterior foi colocado um recorte de dura-máter do mesmo diâmetro da esfera, e na face posterior um recorte de polietileno poroso foi anexado à esfera de luxite por meio de cola (Cianoacrilato estéril). A dura-máter foi fixada ao polietileno poroso por meio de suturas com fio nylon monofilamentar 6.0. Foi realizada cirurgia em um paciente que já havia tido extrusão anterior do implante em um dos olhos, sendo este avaliado em seu pós-operatório imediato, 7º, 15º, 30º dia, além de 3 e 6 meses de pós-operatório quando foi avaliado por meio de tomografia computadorizada. Observou-se bom resultado cosmético, de mobilidade e de volume após adaptação da prótese escleral, não havendo nenhum sinal de infecção, migração ou extrusão do implante até o momento. O caso nos mostrou ser possível a utilização de um implante orbital mais acessível economicamente com resultados semelhantes aos dos implantes biointegráveis.


A new model of orbital implant, matching the low cost of acrylic implants (PMMA) with the advantages of medpor (Porex®) is presented herein. The new implant model consists of a PMMA implant with a dura mater scrap adhered on its anterior face of the same diameter of the acrylic implant and a medpor snip adhered on its posterior face by sterile cyanoacrylate. Dura mater was fixed to medpor with 6.0 mononylon. One patient who presented previous extrusion of the implant was submited to surgery and was evaluated on the 1st, 7th, 15th, 30th postoperative days, and 3 and 6 months after surgery when a computed tomography was performed. A good cosmetic, mobility and volume result was noted after an escleral prosthesis was adapted, with no infection, migration or extrusion of the implant until this moment. This case showed us that it is possible to use a more economic implant model with the same results of medpor (Porex®).


Assuntos
Adulto , Feminino , Humanos , Anoftalmia/cirurgia , Olho Artificial , Implantes Orbitários , Seguimentos , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento
14.
Rev. cir. traumatol. buco-maxilo-fac ; 8(2): 9-14, abr.-jun. 2008.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-490662

RESUMO

A reabilitação de indivíduos com deformidades craniofaciais, decorrentes de traumatismos, más formações congênitas ou tumores, é um objetivo desafiador e complexo. A grande maioria dos recursos e as opções de tratamento trouxeram progresso para a sobrevida dos pacientes, tornando a reabilitação mais urgente e necessária. Com o advento dos implantes osseointegráveis craniofaciais e a melhoria dos materiais protéticos, essas desvantagens estão sendo superadas pelo fato de se conseguir uma maior retenção e estabilidade com o uso de próteses implanto-suportadas, retidas por barras e clipes ou magnetos. As próteses ficaram mais leves, com bordas afinadas, sem o efeito deletério do solvente aplicado para a remoção do adesivo presente na retenção química, resultando em acentuada melhoria funcional, psicológica e social, baseada no restabelecimento da confiabilidade, aceitação, estética e função da prótese, gerando bem-estar e qualidade de vida. Os autores relatam, através de uma revisão de literatura, aspectos sobre a utilização de implantes osseointegrados como meios de retenção para a Prótese Buco-Maxilo-Facial, tais como tipos, suas indicações e contra-indicações, vantagens e desvantagens e aspectos clínicos de interesse para o cirurgião-dentista


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Prótese Maxilofacial , Implantes Orbitários
15.
Arq. bras. oftalmol ; 70(5): 752-755, set.-out. 2007. tab
Artigo em Português | LILACS | ID: lil-470089

RESUMO

OBJETIVO: Avaliar as características dos portadores de cavidades anoftálmicas que desenvolveram extrusão do implante. MÉTODOS: Estudo retrospectivo, observacional, tendo sido avaliados 37 portadores de cavidade anoftálmica que tiveram extrusão do implante de cavidade, na Faculdade de Medicina de Botucatu-UNESP. RESULTADOS: As extrusões ocorreram em cavidades enucleadas ou evisceradas, a maioria delas submetidas a cirurgia em decorrência de phthisis bulbi ou trauma, em geral de 1 a 2 anos após a cirurgia inicial. A deiscência precedeu a extrusão em todos os casos, tendo a extrusão ocorrido com todos os tipos de implantes empregados. CONCLUSÃO: Após a colocação de implantes de cavidade podem ocorrer complicações. A deiscência e extrusão das esferas são possibilidades que podem requerer nova intervenção cirúrgica, para a qual o paciente e o oftalmologista devem estar preparados.


PURPOSE: To evaluate the characteristics of patients with anophthalmic cavity who developed sphere extrusion. METHODS: A retrospective observational study was done evaluating 37 patients with anophthalmic cavity and sphere extrusion at the "Faculdade de Medicina de Botucatu-UNESP". RESULTS: Extrusion was observed in enucleated and eviscerated cavities. The majority of the patients had the eye removed because of phthisis bulbi or trauma and the extrusion happened 1 or 2 years after the surgery. Extrusion was preceded by conjunctival dehiscence and exposure of the sphere and occurred with all used implants. CONCLUSION: Complications after orbital implant placement are a possibility. Dehiscence and sphere extrusion may happen and another surgery would be necessary. The patient and the ophthalmologist have to be prepared for this.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Enucleação Ocular , Evisceração do Olho , Migração de Corpo Estranho/etiologia , Implantes Orbitários/efeitos adversos , Enucleação Ocular/estatística & dados numéricos , Evisceração do Olho/estatística & dados numéricos , Traumatismos Oculares/cirurgia , Doenças Orbitárias/cirurgia , Polímeros , Estudos Retrospectivos , Reoperação/estatística & dados numéricos , Deiscência da Ferida Operatória/complicações , Fatores de Tempo
16.
Arq. bras. oftalmol ; 70(5): 831-838, set.-out. 2007. ilus, tab
Artigo em Inglês | LILACS | ID: lil-470102

RESUMO

PURPOSE: To compare artificial eye amplitudes in enucleated socket with porous polyethylene either spherical or quad-motility implant and study the characteristics of artificial eyes fit with the two orbital implants. METHODS: A total of 21 patients were prospectively studied who underwent enucleation because of an intraocular melanoma and the randomization defined a porous polyethylene either spherical or quad-motility orbital implant. Measurements of the amplitude of the artificial eye were obtained with prism and digital photos. The software Scion Image analyzed the digital photos (www.scioncorp.com) and the quantitative data were allocated to groups. The measurements (height, length, thickness) and weight of the 21 artificial eyes were analyzed. Student's t-test was performed to determine the significance of difference between groups (p<0.05). RESULTS: There was no statistically significant difference of the artificial eye amplitude analyzed by means of prisms between both orbital implants (p>0.05 for all directions). On analyzing the digital photos, the artificial eye with spherical implant showed higher artificial eye amplitude downward (p=0.009) among patients older than 55 years old, rightward (p=0.036) and downward (p=0.008) among the 9 patients with enucleated right eye. Height and length were similar in the 21 artificial eyes but those artificial eyes fit with quad-motility orbital implants were statistically significant thicker (p<0.001) and heavier (p=0.001). CONCLUSIONS: The similar amplitude of movement of artificial eyes was observed with both spherical and quad-motility orbital implants. Artificial eyes fit with quad-motility orbital implant are significantly thicker and heavier than those fit with spherical orbital implant.


OBJETIVOS: Comparar a amplitude de movimento da prótese ocular em cavidade enucleada e com implante orbitário esférico e "quad-motility" e estudar as características das próteses oculares adaptadas com os dois modelos de implantes orbitários. MÉTODOS: Vinte e um pacientes foram prospectivamente estudados após a enucleação devido a melanoma intra-ocular e cuja randomização definiu o implante orbitário de polietileno poroso nos modelos esférico e "quad-motility". Medidas da amplitude da prótese ocular foram obtidas com prisma e fotografia digital. O programa Scion Image analisou as fotos digitais (www.scioncorp.com) e os resultados foram distribuídos por grupos. As medidas (altura, comprimento, espessura) e o peso das 21 próteses também foram analisados. O teste de t foi realizado para determinar a significância da diferença entre os grupos (p<0,05). RESULTADOS: Não houve diferença significante na amplitude do movimento das próteses oculares, analisada com a interposição do prisma em ambos implantes orbitários (p>0,05 em todas as posições). Ao analisar a fotografia digital, as próteses adaptadas com implante esférico apresentaram maior amplitude de movimento na infraversão (p=0,009) para pacientes acima de 55 anos, infraversão (p=0,008) e dextroversão (p=0,036) nos nove pacientes com o olho direito enucleado. Altura e comprimento foram similares nas 21 próteses oculares. Próteses oculares adaptadas com implante "quad-motility" foram significantemente mais espessas (p<0,001) e pesadas (p=0,001). CONCLUSÕES: A amplitude de movimento das próteses oculares foi similar nos implantes esférico e "quad-motility". As próteses oculares adaptadas com implante "quad-motility" são significantemente mais espessas e pesadas do que as adaptadas com implante esférico.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Enucleação Ocular , Olho Artificial , Movimentos Oculares/fisiologia , Polietilenos , Implantação de Prótese , Interpretação Estatística de Dados , Implantes Orbitários , Porosidade , Estudos Prospectivos , Fotografação/métodos
17.
Arq. bras. oftalmol ; 70(4): 639-647, jul.-ago. 2007. tab, ilus
Artigo em Português | LILACS | ID: lil-461954

RESUMO

OBJETIVO: Comparar dois métodos de descontaminação de escleras: tratamento com glicerina versus tratamento com irradiação gama, álcali e glicerina, visando detectar as alterações clínicas e histológicas em cavidades anoftálmicas de coelhos, reconstruídas com esferas de polimetilmetacrilato envolvidas com esclera. MÉTODOS: Trinta e nove coelhos da raça Nova Zelândia foram divididos em 2 grupos: grupo I, cujos animais foram submetidos à enucleação de um olho e reconstrução com esfera de polimetilmetacrilato envolvida em esclera tratada com glicerina; grupo II, quando houve a enucleação e a reconstrução foi feita com esfera de polimetilmetacrilato, envolvida em esclera tratada com irradiação gama, álcali e glicerina. Os 2 grupos foram observados em 4 momentos: 7, 21, 42 e 84 dias após a cirurgia. Decorridos os tempos prefixados, os coelhos foram sacrificados, as órbitas exenteradas, sendo o material processado para emblocamento em parafina, cortado com 5 mm de espessura e corado pelas técnicas de hematoxilina-eosina e tricrômio de Masson. As escleras foram submetidas à análise morfométrica e semiquantitativa. Os resultados foram comparados pelo teste não paramétrico de Mann-Whitney. RESULTADOS: A análise comparativa da vascularização da interface cirúrgica apontou diferença significativa na avaliação feita 21 dias após o implante (P<0,001), tendo o grupo II apresentado neovascularização maior. A comparação da espessura da cápsula fibrosa apontou uma diferença significativa nos momentos correspondentes a 21 dias (P<0,001) e 42 dias (P<0,001), sendo que, nestes dois momentos, o grupo II apresentou cápsula fibrosa mais espessa do que o grupo I. Houve também variação na espessura da esclera, sendo mais espessa no grupo II, também nos momentos pós-implante de 21 dias (P=0,003) e 42 dias (P=0,024). Quando os grupos foram analisados ao longo do período de experimentação, observou-se diminuição da vascularização da interface cirúrgica, entre os...


PURPOSE:To compare two sclera decontamination methods: treatment with glycerin versus treatment with gamma irradiation, alkali and glycerin, aiming to detect the clinical and histological alterations in rabbit anophthalmic sockets reconstructed with sclera-involved polymethylmethacrylate spheres. METHODS:Thirty-nine New Zealand-breed rabbits were divided into two groups: group I, whose animals were submitted to enucleation of one eye and reconstruction with a polymethylmethacrylate sphere involved in glycerin-treated sclera; group II, where there was enucleation, and reconstruction performed with a polymethylmethacrylate sphere involved in sclera treated with gamma irradiation, alkali and glycerin. The two groups were observed at four moments, at 7, 21, 42 and 84 days after surgery. Preset times elapsed, the rabbits were euthanized, sockets were exenterated, the material was processed for embedment in paraffin, cut into 5 æm sections thick and stained with hematoxylin-eosin and Masson's trichrome techniques. The scleras were submitted to morphometric and semiquantitative analysis. Results were compared by Mann-Whitney's non-parametric test. RESULTS: Comparative analysis of vascularization of the surgical interface pointed out a significative difference in the evaluation done 21 days after the implant (P<0.001), with group II showing greater neovascularization. Comparison of the fibrous capsule thickness displayed a significative difference at moments corresponding to 21 days (P<0.001) and 42 days (P<0.001). At both moments, group II presented a thicker fibrous capsule than group I. Likewise, there was variation in sclera thickness, being thicker in group II, at the 21-day post-implant (P=0.003) moment, and at the 42-day moment (P=0.024), as well. Along the experimental period, when groups were analyzed we could observe statistically significative diminution of vascularization in the surgical interface, in group I, as well as in group...


Assuntos
Animais , Masculino , Coelhos , Álcalis , Raios gama , Glicerol , Preservação de Órgãos/métodos , Esclera , Esterilização/métodos , Enucleação Ocular , Microscopia Eletrônica , Modelos Animais , Implantes Orbitários , Polimetil Metacrilato , Cuidados Pós-Operatórios , Esclera/irrigação sanguínea , Esclera/efeitos dos fármacos , Esclera/efeitos da radiação , Fatores de Tempo
18.
Arq. bras. oftalmol ; 70(1): 7-12, jan.-fev. 2007. ilus, graf
Artigo em Português | LILACS | ID: lil-453121

RESUMO

OBJETIVO: Analisar o uso do implante biointegrável Medpor™ em cirurgias de evisceração, enucleação ou implantação secundária em cavidades anoftálmicas. MÉTODOS: Em 61 cirurgias foi utilizado o implante orbitário Medpor™ . Em 18 casos de evisceração, não houve necessidade do revestimento do implante. Em 12 cirurgias de enucleação e implantação secundária o material utilizado para revestir o implante foi duramater homóloga. Nas demais 31 cirurgias, o revestimento foi de material autólogo (esclera, derme, músculo orbicular ou cartilagem auricular), utilizando-se a técnica de "solidéu", recobrindo apenas a superfície anterior do Medpor ™ . RESULTADOS: Os pacientes foram operados no período de janeiro/1998 a dezembro/2004, com tempo de seguimento médio de 30 meses. Em todos os casos houve aceitação do implante, permitindo boa adaptação da prótese. Em dois pacientes ocorreu exposição tardia do implante: o primeiro caso foi corrigido pelo reposicionamento do implante na cavidade, e no segundo caso a exposição foi coberta com um retalho de tarso. CONCLUSÕES: Na nossa experiência o implante Medpor ™ apresenta boa aceitação com taxa de exposição pequena do mesmo (apenas 2 casos), nenhum caso de infecção ou migração, e boa adaptação da prótese em todos os pacientes. O uso de tecido autólogo para revestir a superfície anterior do implante elimina o risco inerente ao uso de tecidos homólogos.


PURPOSE: To analyze the use of Medpor ™ biointegrated implant in surgeries of evisceration, enucleation or secondary implantation in anophthalmic sockets. METHODS: The Medpor™ orbitary implant was used in 61 surgeries. In 18 cases of evisceration the implant's wrapping was not necessary. In 12 enucleation and secondary implantation surgeries the utilized material to wrap the implant was homologous duramater. In the other 31 surgeries, the implant wrapping was made from autologous tissue (sclera, dermis, orbicular muscle or auricular cartilage), utilizing the "cap" technique - covering only the anterior surface of Medpor™. RESULTS: The patients were operated from January 1998 to December 2004 with an average follow-up period of 30 months. In all cases the implant was well accepted, allowing for a good adaptation of the prosthesis. Late exposure of the implant occurred in two patients: the first was corrected by the replacement of the implant in the cavity, while in the second case the exposure was wrapped with a tarsus flap. CONCLUSIONS: In our experience the Medpor ™ implant presents good acceptance, with a small exposure rate (only 2 cases), no infection or migration cases, and a good prosthesis adaptation in all patients. The use of autologous tissue to wrap the implant's anterior surface eliminates the inherent risk of using homologous tissues.


Assuntos
Humanos , Materiais Biocompatíveis/uso terapêutico , Implantes Orbitários , Polietilenos/uso terapêutico , Materiais Biocompatíveis/efeitos adversos , Enucleação Ocular , Evisceração do Olho , Seguimentos , Implantes Orbitários/efeitos adversos , Estudos Prospectivos , Polietilenos/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...